ELECTRICAL: 220 - 240V 50Hz |
Nominal Performance |
Capacity |
425 Watt |
1450 Btu/hr |
365 Kcal/hr |
Input Power |
327 Watt |
Rate current |
2.50 |
COP (W/W) |
1.30 |
Displ.(cm³) |
15.3 |
EER |
4.43 |
|
|
Running Condition |
Ambient Temp |
10~43°C |
Evaporating Temp. |
-5 ~ -15°C |
Voltage Range |
187 ~ 254V |
Max. Winding Temp. |
130°C |
Max. Shell Temp. |
95°C |
Max. Dischange Temp. |
125°C |
Shell Min. Resistance To Pressure |
28 Bar |
|
|
LBP Testing Condition |
Test Condition |
LBP |
Evaporating Temp. |
-23.3 °C |
Ambient Temp. |
32.2 ºC |
Condensing Temp. |
54.4 ºC |
Suction Temp. |
32.2 ºC |
Sub cooling Temp. |
32.2 ºC |
|
|
Performance Data (HBP) |
Capacity |
1300 Watt |
4436 Btu/hr |
1118 Kcal/hr |
Input Power |
605 Watt |
Rate current |
4.10 |
COP (W/W) |
2.15 |
Displ.(cm³) |
15.3 |
EER |
7.33 |
|
|
HBP Testing Condition |
Test Condition |
HBP |
Evaporating Temp. |
7.2 °C |
Ambient Temp. |
35 ºC |
Condensing Temp. |
54.4 ºC |
Suction Temp. |
32.2 ºC |
Sub cooling Temp. |
32.2 ºC |
|
|
Compressor Type |
Compressor Model |
HY153YZ |
Rate Voltage/Frequency |
220-240
~ 50Hz |
Refrigerant Type |
R134a |
Application |
LBP/MBP/HBP |
Cooling Method |
Fan Cooling |
Control device |
Capillary Tube |
Motor Type |
CSIR |
Capacitor |
61 µ F |
|
|